Heparin-binding protein (HBP)
(Latex immunoturbidimetric method)
Heparin Binding Protein (HBP) Detection Kit
------------- Novel acute bacterial infection marker, early indicator of sepsis organ dysfunction.
Biological properties of HBP:
Heparin-Binding Protein (HBP) HBP is a protein secreted by mature neutrophils, when bacterial infection or acute respiratory distress syndrome (ARDS) or acute lung injury (ALI) and respiratory failure occur , its level will increase. Nonbacterial infections do not raise HBP.
HBP is one of the earliest elevated markers of bacterial infection and can be detected in plasma within 1 h of localized or mild bacterial infection. This is an advantage over procalcitonin (PCT).
The level of HBP can also be used to identify various types of postoperative infections. [1
Structural features of HBP
Heparin-binding protein is a neutrophil-derived granule protein whose structure consists of a 222-amino acid single-chain protein containing 8 cysteine residues with aspartic acid residues at positions 100, 114, or 145. Glycosylation site, structurally similar to neutrophil elastin, with 45% homology.
Clinical significance of HBP:
In clinical, heparin-binding protein can be used as a diagnostic index of local infection, auxiliary diagnosis of urinary tract infection, prediction of septic shock and prediction of microcirculatory failure in sepsis.
Comparison of HBP, PCT, CRP HBP: high sensitivity, strong specificity, high positive/negative detection rate, can be detected in the early stage of infection, high concentration in acute bacterial infection, and high concentration in viral infection and non-specific inflammation Low. PCT: It can appear in the early stage of infection, and it increases when the body's infection produces a systemic response. The serum level does not increase significantly during local infection and chronic infection. CRP: A variety of infectious and non-infectious factors (surgery) can cause CRP to rise. It begins to rise 6-8 hours after infection, and reaches a peak at 24-48 hours. The specificity is not ideal.
Liding self-produced OEM inflammation series star product recommendation
product name |
article number |
Heparin Binding Protein OEM Reagent |
LD-OEM-HBP |
Heparin-binding protein calibrator |
LD-OEM-HBP-CAL |
Heparin-binding protein control |
LD-OEM-HBP-QC |
C-reactive protein OEM reagent |
LD-OEM-CRP |
C-reactive protein calibrator |
LD-OEM-CRP-CAL |
C-reactive protein controls |
LD-OEM-CRP-QC |
Serum Amyloid OEM Reagent |
LD-OEM-SAA |
Serum Amyloid Calibrator |
LD-OEM-SAA-CAL |
Serum Amyloid Control |
LD-OEM-SAA-QC |
Procalcitonin OEM Reagent |
LD-OEM-PCT |
Procalcitonin Calibrator |
LD-OEM-PCT-CAL |
Procalcitonin Quality Control |
LD-OEM-PCT-QC |
Liding self-produced heparin-binding protein antigen recommendation
product name |
English abbreviation |
article number |
heparin binding protein antigen |
HBP Ag |
LD-Ag-HBP |
HBP Antigen Diluent |
HBP Dilution |
LD-D-HBP-L |
2-8℃ Stability
37℃ thermal stability
The results showed that the deviation of the heparin-binding protein antigen at 4℃ and 37℃ was within ±10%.
Liding self-produced heparin-binding protein antibody recommendation
product name |
English abbreviation |
article number |
Mouse anti-human HBP monoclonal antibody 01 |
HBP mAb 01 |
LD-mAb-HBP-01 |
Mouse anti-human HBP monoclonal antibody 02 |
HBP mAb 02 |
LD-mAb-HBP-02 |
On the ELISA platform, good reaction performance can still be achieved using our antibodies.
After a large number of experimental studies, it has been shown that better labeling results can be achieved by using the self-produced antibody and the recommended microspheres for labeling.
Standing top recommended microspheres
product name |
English name |
article number |
Microspheres 300 |
Latex300 |
LD-cLATEX-300 |
particle size |
290-320 nm |
Carboxyl content |
0.041-0.061mol/g |
solid content |
10-10.5% |
Recommended process: one-step method
reagent
Combined with market demand, Nanjing Liding Medical Technology Co., Ltd. has successfully developed heparin-binding protein (latex immunoturbidimetric method) after years of research. The parameters and related properties are as follows:
name |
Methodology |
Reagent ratio |
Analysis type |
Secondary/Main wavelength |
Linear range |
sample type |
HBP |
latex-enhanced immune turbidimetry |
R1/S/R2: 160/12/40 |
endpoint method |
0/546nm |
2-200ng/ml |
Sodium citrate plasma |
linear
Precision
|
Inter-assay precision |
within-assay precision |
||
(ng/mL) |
Low |
High |
Low |
High |
N |
5 |
5 |
20 |
20 |
AVE |
19.5 |
91.2 |
19.9 |
94.1 |
CV |
2.8% |
3.8% |
2.0% |
1.2% |
Reagent comparison:
4℃ Stability:
37℃ stability:
Open bottle stability:
HOOK:
Technical Support
In addition to having a comprehensive antigen, antibody, and reagent development platform, LeadingMedcial is more capable of customizing one-stop in vitro diagnostic product solutions, covering registration, R&D, production and other links, providing more comprehensive products and services.
This project can provide flexible service content such as antigen + antibody + OEM reagent + process transfer!!!