About Leading

Setting Sail Once Again! Leading Medical’s Ton-Scale CRP Reagent Launches in Full Swing


Brimming with vitality and bustling with activity at sea, Chinese quality is making waves across the globe! Recently, Leading Medical successfully loaded another batch of ton‑scale CRP reagents onto trucks, setting sail once again for overseas markets and continuing to deliver high‑quality products reliably to IVD customers worldwide.

 

A giant vessel cuts through the waves, its journey never ceasing. This large‑scale delivery of CRP reagents is yet another powerful testament to our robust production capacity and seamless supply‑chain collaboration. We forge quality with meticulous craftsmanship and expand globally through unwavering strength. Leading Medical will continue to unlock its full production potential, ensuring reliable supply, delivering premium products, and providing expert technical services—partnering with customers worldwide to embark on a new chapter of growth.

Stand at the top Full-range C-reactive protein assay reagent

(Latex immunoturbidimetric assay)

 

 

· In-house synthesized carboxylated microspheres: Small particles PL70 (5%, 70–85 nm), large particles PL220 (10%, 215–235 nm)

· Intended use: For the quantitative in vitro determination of C-reactive protein (full-CRP) levels in human serum.

· Principle of the assay: CRP in the sample reacts with a latex‑particle‑sensitized anti‑CRP antibody solution to form an immune complex. The turbidity change is measured at a wavelength of 570 nm, and the extent of this change is directly proportional to the CRP concentration in the sample.



 

Comprehensive CRP Testing Solution

Product Name

Item number

Specifications

Note

CRP reagent

LD-CRP-01

R1:R2 = 1:1

Routine

CRP reagent

LD-CRP-02

R1:R2 = 1:1

Full scale

CRP reagent

LD-CRP-03

R1:R2 = 4:1

Routine

CRP reagent

LD-CRP-04

R1:R2 = 4:1

Ultra-sensitive

Calibrator

LD-CAL-CRP

6×1 mL

Liquid

Quality control material

LD-QC-CRP

2×1 mL

Liquid

CRP antibody

LD-mAb-CRP-05

/

/

CRP antibody

LD-rpAb-CRP-04

/

/

CRP antibody

LD-gpAb-CRP-05

/

/

CRP antigen

LD-Ag-CRP

/

/

Microsphere PL70

LD102031

(70–85) nm

Solid content: 5%

Microsphere PL220

LD102025

(215-235) nm

Solid content: 10%

 

  1. CRP performance

Awarding the contract

 

Precision

 

Inter-batch precision

Intra-assay precision

mg/L

Low

High

Low

High

Hail

9.57

78.9

9.16

68.25

CV

3.12%

2.23%

1.22%

0.89%

 

Accuracy

Sample Number

Target value

Measured value

Relative Deviation (%)

Con1

69.23

66.68

-3.68%

Con2

51.77

49.95

-3.51%

Con3

14.91

14.91

0.00%

Con4

85.95

82.97

-3.47%

Con5

30.24

29.46

-2.58%



Anti-interference

 

Interfering substance

Interferent concentration

Analyte concentration

Test bias

Permissible deviation

Hemoglobin

500 mg/dL

13.82

5.09%

10%

Bilirubin

60 mg/dL

14.47

3.29%

10%

Lactone

1000 mg/dL

15.16

-3.11%

10%

Vitamin C

60 mg/dL

14.93

-5.85%

10%

 

 

Linear

Relevance

Stability after opening at 2–8°C

37°C Accelerated Stability

Calibration and Quality Control – Freeze-Thaw Stability at −20°C

Calibration and Quality Control: 37°C Accelerated Stability

 

 

All
  • All
  • Product Management
  • News